Products
Product Center
BED51 series explosion-proof LED spot (flood) light

1. Applicable to Zone 1 and Zone 2 areas with explosive gas atmospheres;

2. Applicable to explosive gas atmospheres of Class IIA, Class IIB, and Class IIC;

3. Applicable to Zone 21 and Zone 22 areas with explosive dust atmospheres;

4. Suitable for use in explosive dust atmospheres of Class III A, III B, and III C;

5. Applicable to temperature groups T1~T6/T5;

6. Applicable to energy-saving renovation projects and places where maintenance and replacement are difficult;

7. It is widely used for lighting in oil extraction, refining, chemical industry, military industry, textile, food processing, as well as offshore oil platforms, oil tankers and other places.


Application
Oil field
Oil field
Chemical industry field
Chemical industry field
Aerospace field
Aerospace field
Coal mining field
Coal mining field
Metallurgical field
Metallurgical field
Pharmaceutical field
Pharmaceutical field
Brewing field
Brewing field
Fire protection field
Fire protection field
Features
Model meaning

image.png

Implementation standards

GB/T 3836.1、GB/T 3836.2、GB/T 3836.3、GB/T 3836.9、GB/T 3836.31、IEC 60079-0、IEC 60079-1、IEC 60079-7、IEC 60079-18、IEC 60079-31

Features

1. The radiator is designed to be die-cast with special cast aluminum alloy, and its surface is coated with high-voltage electrostatic spraying;

2. Highly corrosion-resistant stainless steel exposed fasteners;

3. Separated structure of light source cavity and power supply cavity;

4. The professionally designed light distribution system boasts high light utilization efficiency, reasonable light distribution, uniform illumination, and no glare;

5. The junction box adopts a labyrinth structure, equipped with silicone rubber sealing strips, which are firmly affixed and have a high level of protection;

6. High-strength tempered glass material, with strong resistance to impact and thermal shock, and high light transmittance;

7. The constant current power supply features wide voltage input, constant current output, and protection functions such as shunt, surge protection, overcurrent protection, open circuit protection, short circuit protection, high temperature protection, and electromagnetic interference resistance;

8. Power factor cosΦ > 0.95;

9. Cable routing.


Detailed specifications


Ecological Cooperation
Ecological Cooperation
Full-service partner
Telephone consultation
Telephone consultation
24/7 hotline service
Submit project requirements
Submit project requirements
Solution presentation within 8 hours
Service and Warranty
Service and Warranty
Technical response within 4 hours